Sky Blue Microsystems
delivering tomorrows products today
Home Produkte Service Jobs Kontakt Über Uns Impressum
 
 
Infortrend RAID Lösungen
Infortrend RAID Lösungen A16F-G2221 Angebot

Fibre to SATA

 

 

 

 

 



 
 
A16F-G2221
  • FC-2G to SATA-II RAID subsystem
  • ASIC 266 architecture capable of unprecedented read/write performance: 386/310 (MB/sec)
  • Enhanced modular enclosure design
  • Highest density in 3U rack space for 16 3.5”drives
  • Up to 64TB capacity per Logical Drive (LD) (OS dependent)
  • DDR Memory up to 2GB
Configuration Model Form Factor
Single A16F-G2221 3U Rackmount
Specifications
  RAID
  Multiple arrays configurable with dedicated or global hot spares
  RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID, and JBOD
  Online expansion by
 
  1. Adding new drives
  2. Copying and replacing drives with drives of larger capacity
  Automatic background rebuild
  Configurable stripe size and write policy per array
  Intelligent Drive Handling
 
  • In degraded mode: Skipping irreparable blocks to continue rebuild
  • In normal operation: Data block verification and repair
  • Task Scheduler: Hands-free Media Scan maintenance
  System Components
 
  • 3U-profile RAID enclosure
  • Single RAID controller
  • 16 drive trays
  • Dual redundant power supplies
  • 2 hot-swappable, dual-speed fan modules
  • Hot-swappable battery module
  Management
  Java-based GUI RAID manager
  Centralized management of multiple arrays over in-band or Ethernet
  Event notification: email, LAN broadcast, fax, SMS, MSN, ICQ, or SNMP traps
  Host-side SES emulation with pass-through to back-end SES emulation
  SNMP 2.0 MIBs with get and set commands
  Firmware-embedded utility via LCD keypad or RS-232C port
  Drive Interface
  Up to 1024 LUNs if sufficiently large memory is used with the proper settings
  3.5-inch, 1-inch high 3Gbps SATA-II disk drives
  16 hot-swappable drive trays
  Automatic bad sector reassignment
  Dedicated bandwidth to each connected drive
  Host Interface
  Auto-negotiate FC-AL, point-to-point, or switched fabric
  Concurrent I/O commands
  Tagged Command queuing up to 256
  Variable stripe size per logical drive
  Optimization setting for random or sequential I/Os
  Maintenance & Availability
  Optional Li-ION battery support
  Immediate array availability
  Drive roaming, array configuration on drives
  Controller voltage and temperature self-diagnostics
  Auto Switch cache policy and Auto Shutdown
  When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
 
  1. Automatically flush cached data and switch the array's caching mode from write-back to write-through
  2. Commence an auto shutdown
  All environmental thresholds associated with this mechanism are user-configurable and the caching mode changes back to write-back once normal condition is restored.
Physical/Electrical
  Interfaces
 
  • 2 SFP sockets, each using a short-wavelength adapter
  • 2 audio jacks for RS-232C serial port (38400, n, 8, 1) and UPS support
  • RJ-45 Ethernet port
  Power Supply
  2 redundant, hot-swappable power supplies with PFC
  Input: 100 to 240VAC, 47 to 63Hz
  Output: +5V, 32A max.; +12V, 32A max.; +3.3V, 30A max.; 460 Watt capacity
  Cooling Fan
  4 cooling fans in 2 separate modules
  Environmental Specifications
 
Operating temperature: 5 to 40° C
Non-operating temperature: - 40º to 60ºC
Relative humidity: 10 to 95%, non-condensing
Operating altitude: sea level to 10,000ft
  Dimensions:
  Chassis dimensions without handles: 131H x 482.6W x 504.3D mm
Chassis dimensions with handles: 130H x 445.0W x 488.2D mm
Package dimensions: 423H x 567W x 772D mm
  System weight (w/o drives):
  Net weight: 28.5kg
Gross weight: 30.5kg
 
 
 
 
 Copyright © 2009 by Sky Blue Microsystems GmbH