RAID |
| |
Multiple arrays configurable with dedicated or global hot spares |
| |
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD |
| |
Online expansion by |
| |
- Adding new drives
- Copying and replacing drives with drives of larger capacity
|
| |
Automatic background rebuild |
| |
Configurable stripe size and write policy per array |
| |
Intelligent Drive Handling |
| |
- In degraded mode: Skipping irreparable blocks to continue rebuild
- In normal operation: Data block verification and repair
|
| |
System Components |
| |
Redundant, hot-swappable components, designed for no single point of failure |
| |
- One (1) EonStor 3U RAID subsystem enclosure
- One (1) RAID controller module [EonStor A16F-S1211] or
Two (2) RAID controller modules [EonStor A16F-R12112]
- One (1) 256MB(or above) SDRAM DIMM module (pre-installed on the controller module) per controller module
- Two (2), hot-swappable, redundant, 460W power supply units
- Two (2), hot-swappable, redundant, dual-fan, cooling modules
- Sixteen (16), hot-swappable, drive trays each with a preinstalled MUX kit
- One (1) LCD panel (pre-installed on the left side front handle)
- Two (2) front handles
|
| |
Management |
| |
Firmware-embedded Java-based GUI RAID manager |
| |
Centralized management of multiple arrays over in-band or Ethernet |
| |
Real-time event notification over email, LAN broadcast, or SNMP traps |
| |
Host-side SES emulation with pass-through to back-end SES emulation |
| |
SNMP 2.0 MIBs with get and set commands |
| |
Firmware-embedded utility via LCD keypad or RS-232C (audio jack) serial port |
| |
Module status LED indicators |
| |
- Two (2) per drive tray
- Two (2) per cooling module
- One (1) per power supply unit
- Eleven (11) per RAID controller module
|
| |
Onboard alarm is triggered when one of the following modules fails: |
| |
- RAID controller module
- Cooling modules
- Power supply unit
- Hard drive
- Serial port communication with PC hyper-terminal
|
| |
Drive Interface |
| |
Up to 1024 LUNs if sufficiently large memory is used with the proper settings |
| |
Supports 3.5", 1" high hard disk drives |
| |
Sixteen (16) hot-swappable drive trays |
| |
Single dual loop across 16 drives within enclosure |
| |
Automatic bad sector reassignment |
| |
Drive hot-swappable via SCA-II connectors |
| |
Dedicated bandwidth to each connected drive |
| |
Host Interface |
| |
Auto-negotiate FC-AL, point-to-point, and switched fabric |
| |
Concurrent I/O commands |
| |
Tagged Command queuing up to 256 |
| |
Variable stripe size per logical drive |
| |
Optimization setting for random or sequential I/Os |
| |
Maintenance & Availability |
| |
Firmware rolling upgrade on redundant RAID controllers |
| |
Synchronized cache over dedicated Fibre channel |
| |
Comes standard with a Li-ION battery module |
| |
Immediate array availability |
| |
Drive roaming, array configuration on drives |
| |
Controller voltage and temperature self-diagnostics |
| |
Auto switch cache policy and Auto shutdown |
| |
When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
1. The cached data will automatically be flushed and the array's caching mode will be switched from write-back to write-through
2. Commence an auto shutdown
All environmental thresholds associated with this mechanism are user-configurable and the caching mode changes back to write-back once normal conditions are restored. |
| Physical/Electrical |
| |
Interfaces: |
| |
- Five (5) SFP sockets per controller module that use short-wavelength adapters
- One (1) RJ-45 Ethernet port per controller module
- Two (2) RS-232C (Audio Jack) serial ports (38400, n, 8, 1) per controller module (one is for terminal emulation, the other is for UPS support)
|
| |
Power Supply Unit (PSU) modules: |
| |
Two (2) redundant, hot-swappable, 460W, PSU modules with PFC. |
| |
| Input: |
90 ~ 260VAC |
| 47 ~ 63Hz |
| Output: |
(Maximum output: 460 Watts) |
| +12.0V |
32A max. |
| + 5.0V |
25A max. |
| + 3.3V |
20A max. |
| Dimensions: |
248.9D x 128.8W x 81.6H mm |
|
| |
Cooling Modules: |
| |
Two (2), redundant, hot-swappable, dual-fan, cooling modules |
| |
Fan speed: |
3600rpm |
| |
Fan size: |
9.7cm |
| |
Airflow per cooling module: |
61 CFM |
| |
* Note there are a total of four fans (two in each cooling module) |
| |
Environmental Specifications: |
| |
Operating temperature: |
5 to 40°C |
| |
Non-operating temperature: |
- 40º to 60ºC |
| |
Relative humidity: |
10~95%, non-condensing |
| |
Operating altitude: |
sea level to 10,000ft |
| |
Dimensions: |
| |
- Without protrusions: 131H x 446.2W x 500D mm
- With protrusions: 131H x 485W x 532D mm
|
| |
Package dimensions: 476H x 592W x 695D mm |
| |
System weight (w/o drives): |
| |
- Net weight: 20kg