Sky Blue Microsystems
delivering tomorrows products today
Home Produkte Service Jobs Kontakt Über Uns Impressum
 
 
Infortrend RAID Lösungen
Infortrend RAID Lösungen A16F-R/S1211 Angebot

Fibre to SATA

 

 

 

 

 



 
 
A16F-R/S1211
  • FC-to-SATA RAID Subsystem
  • Two 2Gbps hub embedded Fibre Channel host channels per controller
  • One 2Gbps hub Fibre Channel expansion channel per controller for SATA JBOD expansion
  • Highest density, 16 drives in 3U rack space
  • Auto switch cache policy and Auto shutdown
  • Dual-active controllers capable of host-transparent failover/failback
  • Up to 64TB capacity per Logical Drive (LD) (OS dependent)
Configuration Model
Form Factor
ODM/SI Board
Dual-redundant A16F-R1211
3U
IFT-7265R-16F2D
Single controller A16F-S1211
3U
IFT-7265R-16F2D
Specifications
  RAID
  Multiple arrays configurable with dedicated or global hot spares
  RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
  Online expansion by
 
  1. Adding new drives
  2. Copying and replacing drives with drives of larger capacity
  Automatic background rebuild
  Configurable stripe size and write policy per array
  Intelligent Drive Handling
 
  • In degraded mode: Skipping irreparable blocks to continue rebuild
  • In normal operation: Data block verification and repair
  System Components
  Redundant, hot-swappable components, designed for no single point of failure
 
  • One (1) EonStor 3U RAID subsystem enclosure
  • One (1) RAID controller module [EonStor A16F-S1211] or
    Two (2) RAID controller modules [EonStor A16F-R12112]
  • One (1) 256MB(or above) SDRAM DIMM module (pre-installed on the controller module) per controller module
  • Two (2), hot-swappable, redundant, 460W power supply units
  • Two (2), hot-swappable, redundant, dual-fan, cooling modules
  • Sixteen (16), hot-swappable, drive trays each with a preinstalled MUX kit
  • One (1) LCD panel (pre-installed on the left side front handle)
  • Two (2) front handles
  Management
  Firmware-embedded Java-based GUI RAID manager
  Centralized management of multiple arrays over in-band or Ethernet
  Real-time event notification over email, LAN broadcast, or SNMP traps
  Host-side SES emulation with pass-through to back-end SES emulation
  SNMP 2.0 MIBs with get and set commands
  Firmware-embedded utility via LCD keypad or RS-232C (audio jack) serial port
  Module status LED indicators
 
  • Two (2) per drive tray
  • Two (2) per cooling module
  • One (1) per power supply unit
  • Eleven (11) per RAID controller module
  Onboard alarm is triggered when one of the following modules fails:
 
  • RAID controller module
  • Cooling modules
  • Power supply unit
  • Hard drive
  • Serial port communication with PC hyper-terminal
  Drive Interface
  Up to 1024 LUNs if sufficiently large memory is used with the proper settings
  Supports 3.5", 1" high hard disk drives
  Sixteen (16) hot-swappable drive trays
  Single dual loop across 16 drives within enclosure
  Automatic bad sector reassignment
  Drive hot-swappable via SCA-II connectors
  Dedicated bandwidth to each connected drive
  Host Interface
  Auto-negotiate FC-AL, point-to-point, and switched fabric
  Concurrent I/O commands
  Tagged Command queuing up to 256
  Variable stripe size per logical drive
  Optimization setting for random or sequential I/Os
  Maintenance & Availability
  Firmware rolling upgrade on redundant RAID controllers
  Synchronized cache over dedicated Fibre channel
  Comes standard with a Li-ION battery module
  Immediate array availability
  Drive roaming, array configuration on drives
  Controller voltage and temperature self-diagnostics
  Auto switch cache policy and Auto shutdown
  When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:

1. The cached data will automatically be flushed and the array's caching mode will be switched from write-back to write-through
2. Commence an auto shutdown

All environmental thresholds associated with this mechanism are user-configurable and the caching mode changes back to write-back once normal conditions are restored.
Physical/Electrical
  Interfaces:
 
  • Five (5) SFP sockets per controller module that use short-wavelength adapters
  • One (1) RJ-45 Ethernet port per controller module
  • Two (2) RS-232C (Audio Jack) serial ports (38400, n, 8, 1) per controller module (one is for terminal emulation, the other is for UPS support)
  Power Supply Unit (PSU) modules:
  Two (2) redundant, hot-swappable, 460W, PSU modules with PFC.
 
Input: 90 ~ 260VAC
47 ~ 63Hz
Output: (Maximum output: 460 Watts)
+12.0V 32A max.
+ 5.0V 25A max.
+ 3.3V 20A max.
Dimensions: 248.9D x 128.8W x 81.6H mm
  Cooling Modules:
  Two (2), redundant, hot-swappable, dual-fan, cooling modules
  Fan speed: 3600rpm
  Fan size: 9.7cm
  Airflow per cooling module: 61 CFM
  * Note there are a total of four fans (two in each cooling module)
  Environmental Specifications:
  Operating temperature: 5 to 40°C
  Non-operating temperature: - 40º to 60ºC
  Relative humidity: 10~95%, non-condensing
  Operating altitude: sea level to 10,000ft
  Dimensions:
 
  • Without protrusions: 131H x 446.2W x 500D mm
  • With protrusions: 131H x 485W x 532D mm
  Package dimensions: 476H x 592W x 695D mm
  System weight (w/o drives):
 
  • Net weight: 20kg
  • Gross weight: 32kg
 
 
 
 
 Copyright © 2009 by Sky Blue Microsystems GmbH